Pedrollo Submersible Pump Control Panels
QEM
QEM - Control Boxes for 4" Single-Phase Borehole PumpsModel | Code | Voltage | Kw | HP | Capacitor | Rated Amps |
QEM 050 | 530ECN05A1 | 230v 50Hz 1Ph | 0.37 | 0.50 | 20 uf | 5 |
QEM 075 | 530ECN07A1 | 230v 50Hz 1Ph | 0.55 | 0.75 | 25 uf | 6 |
QEM 100 | 530ECN10A1 | 230v 50Hz 1Ph | 0.75 | 1 | 35 uf | 7 |
QEM 150 | 530EC15A1 | 230v 50Hz 1Ph | 1.1 | 1.5 | 40 uf | 11 |
QEM 200 | 530ECN20A1 | 230v 50Hz 1Ph | 1.5 | 2 | 60 uf | 13 |
QEM 300 | 530EC30A1 | 230v 50Hz 1Ph | 2.2 | 3 | 75 uf | 18 |
QEM - Control Boxes for 3" Single-Phase Borehole PumpsModel | Code | Voltage | Kw | HP | Capacitor | Rated Amps |
QEM/3 050 | | 230v 50Hz 1Ph | 0.37 | 0.50 | | |
QEM/3 075 | | 230v 50Hz 1Ph | 0.55 | 0.75 | | |
QEM/3 100 | | 230v 50Hz 1Ph | 0.75 | 1 | | |
QEM/3 150 | | 230v 50Hz 1Ph | 1.1 | 1.5 | | |
QET
- The control box is fitted with a selector for manual or automatic operation with the possiblity of attaching a float (or a pressure valve etc)
QET - Control Boxes for 4" & 6" Three-Phase Borehole PumpsModel | Code | Voltage | kW | HP | Rated Amps |
QET 050 | 530TNF05A | 400v 50Hz 3Ph | 0.37 | 0.50 | 1.7 |
QET 075 | 530TNF07A | 400v 50Hz 3Ph | 0.55 | 0.75 | 2 |
QET 100 | 530TNF10A | 400v 50Hz 3Ph | 0.75 | 1 | 2.5 |
QET 150 | 530TNF15A | 400v 50Hz 3Ph | 1.1 | 1.5 | 3.9 |
QET 200 | 530TNF20A | 400v 50Hz 3Ph | 1.5 | 2 | 4.8 |
QET 300 | 530TNF30A | 400v 50Hz 3Ph | 2.2 | 3 | 7 |
QET 400 | 530TNF40A | 400v 50Hz 3Ph | 3 | 4 | 9 |
QET 550 | 530TNF55A | 400v 50Hz 3Ph | 4 | 5.5 | 11.5 |
QET 750 | 530TNF75A | 400v 50Hz 3Ph | 5.5 | 7.5 | 15.5 |
QET 1000 | 530AD100A | 400v 50Hz 3Ph | 7.5 | 10 | 21.5 |
QET 1250 | 530AD125A | 400v 50Hz 3Ph | 9.2 | 12.5 | 23.5 |
QET 1500 | 530AD150A | 400v 50Hz 3Ph | 11 | 15 | 27.5 |
QET 2000 | 530AD200A | 400v 50Hz 3Ph | 15 | 20 | 36 |
QET 2500 | 530AD250A | 400v 50Hz 3Ph | 18.5 | 25 | 45 |
QET 3000 | 530AD300A | 400v 50Hz 3Ph | 22 | 30 | 54 |
QET 4000 | 530AD400A | 400v 50Hz 3Ph | 30 | 40 | 68 |
QET 5000 | | | | 50 | |
QSM
- The control box is fittted with a selector for manual or automatic operation with the possibility of attaching a float (or a pressure valve etc) and fluid probes which protect the pump from operating when dry
QSM - Control Boxes for 4" Single-Phase Pumps, with Level ProbesModel | Code | Voltage | Kw | HP | Capacitor | Rated Amps |
QSM 050 | 530MFLCN05A1 | 230v 50Hz 1Ph | 0.37 | 0.50 | 20 uf | 5 |
QSM 075 | 530MFLCN07A1 | 230v 50Hz 1Ph | 0.55 | 0.75 | 25 uf | 6 |
QSM 100 | 530MFLCN10A1 | 230v 50Hz 1Ph | 0.75 | 1 | 35 uf | 7 |
QSM 150 | 530MFLC15A1 | 230v 50Hz 1Ph | 1.1 | 1.5 | 40 uf | 11 |
QSM 200 | 530MFLCN20A1 | 230v 50Hz 1Ph | 1.5 | 2 | 60 uf | 13 |
QSM 300 | 530MFLC30A1 | 230v 50Hz 1Ph | 2.2 | 3 | 75 uf | 18 |
QST
- The control box is fittted with a selector for manual or automatic operation with the possibility of attaching a float (or a pressure valve etc) and fluid probes which protect the pump from operating when dry
QST - Control Boxes for 4" & 6" Three-Phase Pumps, with Level ProbesModel | Code | Voltage | kW | HP | Rated Amps |
QST 050 | 530TFLC05A | 400v 50Hz 3Ph | 0.37 | 0.50 | 1.7 |
QST 075 | 530TFLC07A | 400v 50Hz 3Ph | 0.55 | 0.75 | 2 |
QST 100 | 530TFLC10A | 400v 50Hz 3Ph | 0.75 | 1 | 2.5 |
QST 150 | 530TFLC15A | 400v 50Hz 3Ph | 1.1 | 1.5 | 3.9 |
QST 200 | 530TFLC20A | 400v 50Hz 3Ph | 1.5 | 2 | 4.8 |
QST 300 | 530TFLC30A | 400v 50Hz 3Ph | 2.2 | 3 | 7 |
QST 400 | 530TFLC40A | 400v 50Hz 3Ph | 3 | 4 | 9 |
QST 550 | 530TFLC55A | 400v 50Hz 3Ph | 4 | 5.5 | 11.5 |
QST 750 | 530TFLC75A | 400v 50Hz 3Ph | 5.5 | 7.5 | 15.5 |
QST 1000 | 530ADL100A | 400v 50Hz 3Ph | 7.5 | 10 | 21.5 |
QST 1250 | 530ADL125A | 400v 50Hz 3Ph | 9.2 | 12.5 | 23.5 |
QST 1500 | 530ADL150A | 400v 50Hz 3Ph | 11 | 15 | 27.5 |
QST 2000 | 530ADL200A | 400v 50Hz 3Ph | 15 | 20 | 36 |
QST 2500 | 530ADL250A | 400v 50Hz 3Ph | 18.5 | 25 | 45 |
QST 3000 | 530ADL300A | 400v 50Hz 3Ph | 22 | 30 | 54 |
QST 4000 | 530ADL400A | 400v 50Hz 3Ph | 30 | 40 | 68 |
EVOLUTION
- The control box contains an electronic card which makes it possible to reguate the threshold at which the protection against power overlads and short circuits intervenes, the electronic card also controls the value of cos' in order to prevent dry operating of the pump without the help of fluid level probes.
- the control box may be connected to a float switch (or pressure switch etc)
EVOLUTION - Control Boxes for 4" & 6" Borehole PumpsModel | Code | Voltage | Rated Amps |
EVOLUTION MONO | 532DOM003M | 230v 50Hz 1Ph | from 2 to 18 |
EVOLUTION TRI/1 | 532DOM075T | 400v 50Hz 3Ph | from 2 to 16 |
EVOLUTION TRI/2 | 532DOM100T | 400v 50Hz 3Ph | from 16 to 22 |
QES
- The control box is pre-set for connection with the thermal protector inserted in the windows of the drainage pumps VXCm30, VXCm30-F, MCm30, MCm30-F.
- QES 300 MONO-AL control box with contacts for connection to an auxillary float switch for level alarm.
QES - Control Boxes for Single-Phase Drainage PumpsModel | Code | Voltage | Kw | HP | Capacitor | Rated Amps |
QES 300 MONO | 52VX300A1 | 230v 50Hz 1Ph | 2.2 | 3 | 60 uf | 16 |
QES 300 MONO-AL | 52VX300A1AL | 230v 50Hz 1Ph | 2.2 | 3 | 60 uf | 16 |
QES
- The control box is fitted with a selector for manual or automatic operation with the possibility of attaching a float, and with the thermal protector inserted in the winding of the draiange pumps VXC, VXC-F, MC, MC-F.
QES - Control Boxes for Three-Phase Drainage PumpsModel | Code | Voltage | kW | HP | Rated Amps |
QES 150 | 532QES150A | 380-415v 50Hz 3Ph | 1.1 | 1.5 | 4.2 |
QES 200 | 532QES200A | 380-415v 50Hz 3Ph | 1.5 | 2 | 5.2 |
QES 300 | 532QES300A | 380-415v 50Hz 3Ph | 2.2 | 3 | 6.5 |
QES 400 | 532QES400A | 380-415v 50Hz 3Ph | 3 | 4 | 8 |
QED1
- The control box contains an electronic card which makes it possible to regulate the value of the current which the protection intervenes against overloads and short circuits.
- The control box is pre-set for connection with the thermal protector inserted in the winding of the drainage pumps VXC, VXC-F, MC, MC-F and of three floats (operation, stop, and level alarm)
QED1 - Electronic Control Box for One Drainage PumpModel | Code | Voltage | Rated Amps |
QED1 MONO | 533QED01M | 230v 50Hz 1Ph | from 2 to 18 |
QED1 TRI | 533QED01T | 400v 50Hz 3Ph | from 2 to 9 |
QED2
- The control box contains an electronic card which makes it possible to regulate the value of the current which the protection intervenes against overloads and short circuits.
- The control box is pre-set for connection with the thermal protector inserted in the winding of the drainage pumps VXC, VXC-F, MC, MC-F and of four floats (successive operation of the first pump, operation of the second pump, stop, and level alarm)
QED2 - Electronic Control Box for Two Drainage PumpsModel | Code | Voltage | Rated Amps |
QED2 MONO | 533QED02M | 230v 50Hz 1Ph | from 2 to 18 |
QED2 TRI | 533QED02T | 400v 50Hz 3Ph | from 2 to 9 |
Tariff CodesFor a current not exceeding 16 A | 85363010 |
For a current exceeding 16 A but not exceeding 125 A | 85363030 |
For a current exceeding 125 A | 85363090 |
Download Pedrollo Submersible Pump Control Boxes PDF
Product Options
£84.00
Customers who bought this also bought…
Product Code | PED6BGKU93 |
Condition | New |