Braun HZ5-DR Digital Pulse Meter
Oil meters, with Digital Counter & Pulser, and rugged metal exterior
Calibrated, EU Qualification Approval Number D01.5.223.03. Calibration Validity 10 Years
IMPORTANT - All meters must be fitted with a pre-filter of 100 Microns, Maximum. Ingress of particles over 100 microns may lead to wear and or jamming of the movement, and will not be covered by Warranty
Meters are supplied as standard with BSP Female threaded ports, pointing both outwards and downwards from the underside of the meter.
Pulse Output
- Connection via screw-clamp terminals
- Reed contact: max. 30 VDC | Imax = 6 mA
- Rs = 4.7 K-Ohm/0.6W (observe polarity)
- Principle: The power circuit of a counter or other registering device attached to the plus and minus terminal clamps is closed via the reed contact and 4.7 K-Ohm impedance. The input impedance should be at least 50 K-Ohm to ensure that the additional counter reaches its switching threshold.
- Pulse value: 1 pulse = 0.02l | 50 pulses = 1l
- Maximum frequency at 60l/h approx. 1Hz (Due to the reed contact [-debouncing-], use remote counter with dampened input)
LCD Counter
- 6-digit with 0.1 l display resolution
- 3V/950 mAh lithium-ion battery
- Lasts at least 9 years (depending on temperature and moisture)
Environmental Conditons
- 0 to 60 degrees Celsius
- Max. 85% RH, non-condensing
- CE-compliant electromagnetic compatibility
- DIN EN 61326-1 2006-10 version
Function of Counter and Pulse Generator
- The 6-digit LCD display with 6mm high figures has a display resolution of 0.1 litres (1 decimal point).
- A built-in 3V/950 mAh lithium battery supplies power. Its operational life is approx. 9 years.
- The internal reed contact supplies 50 pulses per litre, or 20ml per pulse, to the output clamps. The electronics in the counter turn this into a decadic value with 0.1 litres after 5 pulses in order to operate the counter.
- Due to the 4.7 K-Ohm internal impedance, a connected remote counter should have an input impedance of at least 50 K-Ohm.
- The mounting instructions must be observed without fail if an additional counter is connected to the output.
Suitable for Fuel Types;
- Heating Fuel, Extra Light / Light / Medium
- Kerosene
- Naphtha
- Diesel
- Petrol
- Lubricating Oils
Standard Specification (Non Pulsed) | Braun HZ5-DR |
Connection Threads | DIN 3852-X-G 1/8″ internal |
Nominal Pressure | 25 Bar |
Pressure Loss | 0.05 Bar to 0.2 Bar |
Minimum Temperature | -10 Celcius |
Maximum Temperature | +60 Celcius |
Maximum Flow Rate | TBC lph (OUTSIDE OF CALIBRATED FLOW RANGE) |
Calibrated Maximum Flow Rate | 40 lph |
Calibrated Minimum Flow Rate | 0.7 lph |
Approximate Starting Flowrate | 0.7 lph |
Pulse | 1 Pulse per 0.1 L / 10 PPL |
To Suit Burner Power Rating | 7 kW to 400 kW |
Maximum Permissible Error | ±1% of reading |
Smallest Readable Amount | 0.01 Litres |
Registration Capacity | 0.1 L to 9,9999.98 L |
Safety Filter Mesh Size | TBC |
Dirt Filter Mesh Size | TBC |
Volume of Measuring Chamber | TBC |
Ingress Protection | IP50 |
Dimensions & Weight | Braun HZ5-DR |
Height | |
Width | |
Depth | |
Weight Without Couplings | 600 g |
Download Braun HZ5-DR Datasheet PDF
Download Braun HZ5-DR Instructions PDF